addaScan home
Assessment
Application guide · Surfaces and visible weld defects

Inspecting visible weld defects around battery sealing pins

By Frank GuoPublished Updated 5 min read

// The inspection task

Battery sealing-pin inspection can confuse a cleaning mark with weld damage if the inspection region drifts. Establish the terminal centre and surrounding geometry first, then place separate regions over the cleaning ring and the weld. A local anomaly should be judged with its physical context rather than as an isolated dark or bright patch.

Application guide by addaScanCompare the inspection task, imaging conditions and validation steps with your own production line.

Inspection task
Battery sealing-pin weld inspection
Decision focus
battery sealing-pin weld inspection
Station planning
Reject a bad location before interpreting the surface
Illustrative scenario
a suspected weld fault follows the cleaning ring
Application images

Local weld features around the sealing pin

The application images show the physical product and imaging conditions. The engineering diagram below explains the inspection logic and recovery decisions.

Sealing-pin weld details. Original magnified regions retain the inspection overlays around visible weld features.
Sealing-pin weld details

Original magnified regions retain the inspection overlays around visible weld features.

Select an image to view it at full size.

Keep the terminal, cleaning ring and weld region separate

Swipe across the table to compare all columns →

Compare the options against the product and station requirements
ConditionApproach to evaluateSelection check
Ring continuity and positionEvaluate geometric checks around the pin reference.Define permitted displacement and missing segments.
Irregular surface faultsEvaluate segmentation with regional labels.Include normal residue and cleaning marks.
New station or pin variantRevalidate imaging and challenge samples.A copied model is not a complete station acceptance.

Reject a bad location before interpreting the surface

Choose locating features that survive normal cleaning and weld variation. Check the fit quality and permitted displacement before moving the inspection regions. If the terminal is only partly visible, a numerically available centre may still be unreliable. Return invalid location when the necessary geometric evidence is absent.

Use the cleaning ring as contextual information, not as an interchangeable reference for the weld itself. Illumination that makes a ring edge prominent may also magnify harmless surface marks. Compare accepted cleaning variation with real weld-related appearance faults. Where the classes overlap visually, a second illumination view or controlled review is preferable to an unsupported high-confidence label.

Schematic terminal centre surrounded by weld and cleaning rings, with a highlighted local feature near the outer inspection band.
The weld zone and cleaning ring are separate regions around the located terminal. A misplaced region can turn an accepted cleaning mark into a false weld fault.

On a small screen, scroll across the diagram to inspect the labels.

Worked example: a suspected weld fault follows the cleaning ring

In an illustrative image, the defect tool highlights a crescent beside the terminal. The registered weld region has shifted onto the cleaning boundary. Correct the localisation and reacquire; the original result is an invalid-region event, not confirmed weld damage.

On a correctly located part, a similar crescent lies within the normal cleaning ring and matches approved variation. A separate raised-looking spot lies inside the required weld zone and meets the visible-spatter criterion. Keep the full terminal view and the local crop together so the operator can see why these features receive different outcomes. Hold the part when required context is missing or the feature remains ambiguous. Reinspection must use the same identified part, and the final release or rejection should preserve the earlier attempt and its reason.

Swipe across the table to compare all columns →

Evidence, decision and recovery for locate the terminal before classifying the crescent
Observed evidenceInspection decisionAction and retained record
The suspected crescent coincides with the cleaning boundary after a shifted terminal location.Region-placement failure is suspected.Keep the original transform and full terminal image, correct the reference and repeat the identified part's inspection before classifying the feature.
A correctly placed weld region contains a qualified local spatter feature.Visible weld-zone failure, independent of normal cleaning marks.Record the regional context and defect crop, reject or hold the part and preserve the physical handling confirmation.
Terminal geometry is partly hidden and the centre fit lacks required evidence.Location invalid; subsequent surface decisions are unavailable.Re-present the part or use the agreed exception route. Retain the missing-reference reason rather than adding it as a normal training example.

Make normal cleaning variation part of acceptance work

Challenge off-centre presentation, strong cleaning marks, weak terminal edges and known weld faults. Track localisation failures separately from surface-defect decisions. Otherwise a rise in false rejects may prompt unnecessary model changes when the actual problem is fixture movement.

This station evaluates visible external features in defined regions. Sealing integrity and internal weld quality require their own evidence. Store the recipe, region placement and image with the part event so any process investigation can distinguish geometry, cleaning appearance and weld-zone observations.

Swipe across the table to compare all columns →

Challenge samples and the evidence required before acceptance
ChallengeWhat to verify
Defect in weld, inner and cleaning regionsCheck regional coverage separately.
Normal welding dustMeasure false rejects under the agreed cleanliness policy.
Shifted pin imageVerify region alignment remains valid.
Ambiguous low-contrast faultDefine a hold or review response.

Sealing-pin weld samples and acceptance criteria

Provide pin geometry, zone definitions, weld/cleaning variation and the criteria used by the process team.

Use the machine vision lighting guide to develop the next step.

Define the wider inspection responsibility in surface defect detection.

Translate these view and interface requirements into equipment choices with algorithm tools.

Use the optical and recovery challenges above when applying the architecture choices in vision-system comparison guide.

Scope and budget

Use the vision system cost guide to consider views, local positioning and reject handling without treating a visible weld check as a complete weld test.

Testing and handover

The testing and handover process should include surface variation around the pin and the separate evidence needed to assess weld integrity.

// Based in Johannesburg · Serving South Africa

Assess the visible sealing-pin weld

Provide pin geometry, zone definitions, weld/cleaning variation and the criteria used by the process team.